| | 108 | |
| | 109 | |
| | 110 | [=#np7] |
| | 111 | == NP7 CAN not functional |
| | 112 | |
| | 113 | Issue: |
| | 114 | * The CAN transceiver is missing a pull-down on its STBY signal rendering it unable to send/recv. |
| | 115 | |
| | 116 | Resolution: |
| | 117 | * Properly terminate the STBY signal |
| | 118 | |
| | 119 | Affected Product: |
| | 120 | * GW6404-A (PCB 02210154-00) |
| | 121 | * GW6304-A/B/C/D (PCB 02210153-00, PCB 02210153-01, PCB 02210153-02, PCB 02210153-03) |
| | 122 | * GW6204-A (PCB 02210152-00) |
| | 123 | |
| | 124 | Fixed in: |
| | 125 | * GW6404-B.1 (PCB 02210154-01) |
| | 126 | * GW6304-E (PCB 02210153-04) |
| | 127 | * GW6204-B (PCB 02210152-01) |
| | 128 | |