Changes between Version 17 and Version 18 of venice/errata


Ignore:
Timestamp:
04/03/2024 09:53:10 PM (5 weeks ago)
Author:
Tim Harvey
Comment:

added VN9 errata

Legend:

Unmodified
Added
Removed
Modified
  • venice/errata

    v17 v18  
    208208
    209209
     210[=#VN9]
     211== VN9 GSC v63/v64 unintentional reset during supervisor enable
     212
     213Issue:
     214 * When the voltage supervisor is enabled (done in U-Boot) the GSC (with firmware v63 or v64) will unintentionally reset causing the RTC to clear. Note this only occurs for newer baseboard models which have a GSC LDO regulator (see resolved on in [#vn8 errata VN8])
     215
     216Resolution:
     217 * Update to GSC v65 firmware
     218
     219Affected Products:
     220 * The following baseboards with GSC v63 or v64 firmware
     221  * GW710x-E+
     222  * GW720x-F+
     223  * GW730x-F+
     224  * GW740x-C+
     225
     226
     227