| 2091 | == FSA Replacement and Removal |
| 2092 | |
| 2093 | FSA adapters are not designed or meant to be repeatably swapped or replaced. However, there may be special circumstances when this may need to be performed. |
| 2094 | |
| 2095 | The mating connector between the FSA and the SBC is very fine pitched. The connector is only rated for 30 mating cycles. |
| 2096 | |
| 2097 | To unmate this connector, lift evenly across the header, making sure that each side stays parallel to each other. Do not lift one side at a time. Do not unmate by tilting at all. |
| 2098 | |
| 2099 | Overall, a lot of caution is required and it is recommended to order the SBC with the proper FSA adapters already installed. |