    20201. Use a metal enclosure with minimal openings. Make sure if the enclosure is painted that the paint is removed/masked in areas that come in direct contact with the connector shields. For example, the Ethernet RJ45 shields should make direct contact with the enclosure metal. Any paint in the cutout hole should be removed/masked.
    21 2. Use shielded cables for power, Ethernet, USB, etc. Make sure the shields are terminated at both ends during testing. See below for shielded vs non-shielded connectors.
     212. Use shielded cables for power, Ethernet, USB, etc. Make sure the shields are terminated at both ends during testing. See below for shielded vs non-shielded RJ45 connectors.
    2222
    2323Non-shielded RJ45