Version 3 (modified by 2 years ago) ( diff ) | ,
---|
Venice Ethernet
Venice Ethernet device mapping:
Board | Connector | Silkscreen | U-Boot | Linux | MAC/Phy | Notes |
---|---|---|---|---|---|---|
GW740x | J21 | Eth#0 | eth1 | eth1 | IMX8MP EQOS RGMII GPY111 | 802.3at class5 PoE |
- | - | eth0 | eth0 | IMX8MP FEC RGMII KSZ9477 Port5 | cpu uplink | |
J22 | Eth#1 | lan1 | lan1 | KSZ9477 Port1 | Passive 8-60V PoE | |
J22 | Eth#2 | lan2 | lan2 | KSZ9477 Port2 | ||
J23 | Eth#3 | lan3 | lan3 | KSZ9477 Port3 | ||
J23 | Eth#4 | lan4 | lan4 | KSZ9477 Port4 | ||
J24 | Eth#5 | lan5 | lan5 | KSZ9477 Port5 | ||
GW730x | J20 | Eth#0 | eth0 | eth0 | IMX8MM FEC RGMII GPY111 | 802.3at class4 PoE |
J21 | Eth#1 | eth1 | eth1 / enp6s0 | PCI LAN7430 or 88E8057 | Passive 8-60V PoE | |
GW720x | J17 | eth0 | eth0 | IMX8MM FEC RGMII GPY111 | 802.3at class4 PoE | |
J17 | eth1 | eth1 / enp5s0 | PCI LAN7430 or 88E8057 | Passive 8-60V PoE | ||
GW710x | J16 | Ethernet | eth0 | eth0 | IMX8MM FEC RGMII GPY111 | Passive 8-60V PoE |
- Port ordering above is from leftmost RJ45 on board when viewing the front-panel
- if 'net.ifnames=0' kernel parameter is specified network interfaces on enumerated busses such as pci/usb are numbered sequentially (ie eth1 instead of enp6s0). See Predictable Interface Names for details
- for boards like the GW740x which have a multi-port GbE switch, bandwidth is shared across the downstream ports