Changes between Version 25 and Version 26 of ventana/errata


Ignore:
Timestamp:
07/26/2021 03:20:16 PM (3 years ago)
Author:
Tim Harvey
Comment:

fixed formatting

Legend:

Unmodified
Added
Removed
Modified
  • ventana/errata

    v25 v26  
    525525
    526526Issue:
    527  * An errata in the MSP430FR5847 used as the GSC (GSCv3) for Ventana
    528 GW5910/GW5913 single board computers can cause unexpected GSC lockup
    529 events. The effects of a GSC lockup can be described as:
     527 * An errata in the MSP430FR5847 used as the GSC (GSCv3) for Ventana GW5910/GW5913 single board computers can cause unexpected GSC lockup events. The effects of a GSC lockup can be described as:
    530528  - failure of board to boot due to inability to read board I2C EEPROM
    531529  - failure to read the I2C RTC and update the system time