  • enclosures

    v35 v36  
    125125 * [wiki:ventana/thermal_management#ThermalEnclosures]
    126126
     127== Custom Enclosure Guidelines
     128 * Metal enclosures are typically recommended due to better EMI shielding, etc compared to plastic.
     129 * It is recommended to heatsink the CPU to the outer edge of the enclosure
     130 * It is possible to use thermal pads on both sides of the heat slug between the CPU and the enclosure, each having a max compression of 63%. While less thermally efficient than using paste on one side and a pad on the other, using pads on both sides was more forgiving of tolerances and provided sufficient thermal dissipation.
     131 * For hetasink forces, a general rule of thumb is a maximum pressure / force of 59 gm-f per square mm of solderable pad area. (reference sec 8.1 [https://www.nxp.com/docs/en/application-note/AN13656.pdf  NXP AN13656.pdf]
     132 * For EMI purposes, it is recommended for the metal tangs of the RJ45 ethernet jacks to make constant contact with the metal enclosure