Changes between Version 36 and Version 37 of enclosures
- Timestamp:
- 09/25/2026 07:36:29 PM (2 hours ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
enclosures
v36 v37 129 129 * It is recommended to heatsink the CPU to the outer edge of the enclosure 130 130 * It is possible to use thermal pads on both sides of the heat slug between the CPU and the enclosure, each having a max compression of 63%. While less thermally efficient than using paste on one side and a pad on the other, using pads on both sides was more forgiving of tolerances and provided sufficient thermal dissipation. 131 * For hetasink forces, a general rule of thumb is a maximum pressure / force of 59 gm-f per square mm of solderable pad area. (reference sec 8.1 [https://www.nxp.com/docs/en/application-note/AN13656.pdf NXP AN13656.pdf]132 131 * For EMI purposes, it is recommended for the metal tangs of the RJ45 ethernet jacks to make constant contact with the metal enclosure 132 * For hetasink forces, a general rule of thumb is a maximum pressure / force of of solderable pad area: 133 * 59 gm-f per square mm (The heatsink force for the exposed die for the i.MX8M plus (15x15) package static force) 134 * i.MX8M Plus (15x15 package) = 3.5 lbs-f max, 3.4 lbs-f recommended (static force) 135 * i.MX95 (19x19 package) = 10 lbs-f max, 7 lbs-f recommended (static force) 136 * (reference sec 8.1 [https://www.nxp.com/docs/en/application-note/AN13656.pdf NXP AN13656.pdf] 133 137
