  • expansion/gw16167

    v25 v26  
    839839More information on mesh and 802.11s can be found on our [https://trac.gateworks.com/wiki/wireless/wifi/mesh mesh networks] wiki page.
    840840
     841
     842[=#thermal]
     843== Thermal
     844While the MM8108 can operate from -40C to +85C. Currently, once the chip reaches 85C internally the transmitter is disabled to prevent damage. MorseMicro is exploring making this threshold configurable as well as options to implement a duty cycle or a reduced power mode instead of a full disable.
     845
     846You can obtain the value of the internal temperature reading via {{{morse_cli}}}:
     847{{{#!bash
     848morse_cli -i wlan0 stats | grep Temp
     849}}}
     850
     851
    841852[=#performance]