| 108 | |
| 109 | |
| 110 | [=#np7] |
| 111 | == NP7 CAN not functional |
| 112 | |
| 113 | Issue: |
| 114 | * The CAN transceiver is missing a pull-down on its STBY signal rendering it unable to send/recv. |
| 115 | |
| 116 | Resolution: |
| 117 | * Properly terminate the STBY signal |
| 118 | |
| 119 | Affected Product: |
| 120 | * GW6404-A (PCB 02210154-00) |
| 121 | * GW6304-A/B/C/D (PCB 02210153-00, PCB 02210153-01, PCB 02210153-02, PCB 02210153-03) |
| 122 | * GW6204-A (PCB 02210152-00) |
| 123 | |
| 124 | Fixed in: |
| 125 | * GW6404-B.1 (PCB 02210154-01) |
| 126 | * GW6304-E (PCB 02210153-04) |
| 127 | * GW6204-B (PCB 02210152-01) |
| 128 | |