Changes between Version 150 and Version 151 of pcn


Ignore:
Timestamp:
09/30/2025 11:45:52 PM (2 hours ago)
Author:
Ryan Erbstoesser
Comment:

adjust 119 for vn11

Legend:

Unmodified
Added
Removed
Modified
  • pcn

    v150 v151  
    11111111[=#pcn119]
    11121112[=#PCN119]
    1113 == PCN119 - Venice Errata VN10 - Invalid GSC Registers in Development Environment Interfere with Board Power  ==
     1113== PCN119 - Venice Errata VN11 - Invalid GSC Registers in Development Environment Interfere with Board Power  ==
    11141114* Date: 09-30-2025
    11151115* The Venice and VeniceFLEX SBCs have a new errata, VN11. This errata typically affects SBCs in a development environment when a JTAG dongle (GW16099) is being used. If the JTAG is plugged into a SBC via the ribbon cable with the USB portion not connected to a PC, the board can remain in a infinite sleep state and removing the coin cell battery resets this. A revised GW16099 and new GSC firmware (v67) have been released to resolve this.