Changes between Version 17 and Version 18 of venice/errata
- Timestamp:
- 04/03/2024 09:53:10 PM (8 months ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
venice/errata
v17 v18 208 208 209 209 210 [=#VN9] 211 == VN9 GSC v63/v64 unintentional reset during supervisor enable 212 213 Issue: 214 * When the voltage supervisor is enabled (done in U-Boot) the GSC (with firmware v63 or v64) will unintentionally reset causing the RTC to clear. Note this only occurs for newer baseboard models which have a GSC LDO regulator (see resolved on in [#vn8 errata VN8]) 215 216 Resolution: 217 * Update to GSC v65 firmware 218 219 Affected Products: 220 * The following baseboards with GSC v63 or v64 firmware 221 * GW710x-E+ 222 * GW720x-F+ 223 * GW730x-F+ 224 * GW740x-C+ 225 226 227