     211== VN9 GSC v63/v64 unintentional reset during supervisor enable
     212
     213Issue:
     214 * When the voltage supervisor is enabled (done in U-Boot) the GSC (with firmware v63 or v64) will unintentionally reset causing the RTC to clear. Note this only occurs for newer baseboard models which have a GSC LDO regulator (see resolved on in [#vn8 errata VN8])
     215
     216Resolution:
     217 * Update to GSC v65 firmware
     218
     219Affected Products: