Changes between Version 18 and Version 19 of gsc


Ignore:
Timestamp:
08/08/2018 09:21:38 PM (6 years ago)
Author:
Ron Eisworth
Comment:

Added comment on battery voltage monitoring

Legend:

Unmodified
Added
Removed
Modified
  • gsc

    v18 v19  
    174174|| fan0_point5 || 0x36           || Temperature   || Deg C/10    || Fan controller set point 5      ||
    175175
    176  * Note that bat rail cannot be measured until board power is turned off for one second or more. When power is off, we monitor the bat voltage every 9 hours. When the board is fully powered on and booted into Linux, the bat reading cannot be continually updated and reports the last read voltage when the board was powered off.
    177176 * Note that the above descriptions are board-specific. Please see the board [http://www.gateworks.com/usermanuals Hardware User Manual] 'System Temperature and Voltage Monitor' section for details.
    178177
     
    242241
    243242For Ventana i.MX6 processor temperature, see [wiki:ventana/thermal here]
     243
     244[=#batread]
     245== Battery Voltage Reading ==
     246The battery voltage rail (bat) cannot be measured until board power is turned off for two seconds or more. When power is off, the GSC monitors the battery voltage every 18 hours. When the board is fully powered on and booted into Linux, the battery voltage reading will be the last read voltage when the board was powered off. For always on applications where battery voltage needs to be accurate, it is suggested to have the GSC do a powercycle for two seconds at a convenient time to get an updated battery voltage reading.
    244247
    245248